Key Info
Range
1KVA to 10KVA
Phase
1-1 Phase
Optional Features
Parallel Port / USB / Temperature Detection
Efficiency
95% (up to 98% in ECO Mode)
Input Power Factor
0.99
Parallel Technology
Advanced Digital Parallel Technology
50 / 60 Hz frequency
Yes, Auto Sensing
Communications
RS232 (Standard), USB / RS485 / Dry contacts / SNMP / Battery Temperature Compensation (optional)
Transfer time
Mains Mode to Battery Mode: 0 ms.
Total harmonic distortion (THDv)
1% (linear load), 5% (non-linear load)
Range

1KVA to 10KVA

Phase

1-1 Phase

Input Power Factor

0.99

Efficiency
95% (up to 98%)

Optional Features

Parallel Port, USB,
Temp Detection

Parallel Technology

Advanced Digital Parallel
Tech

Communications

RS232 (Std), USB, RS485, SNMP, BTC

Total Harmonic Distortion

1% (linear),
5% (non-linear)

EnerTech is a leading brand of UPS manufacturers in India and one of the best online UPS suppliers. EnerTech offers a wide range of Online UPS from 1KVA to 10KVA based on the latest technology, built to withstand harsh environmental conditions and unstable power scenarios—perfect for everything from small offices to mission-critical applications.

Our range of ETXi Online UPS consists of new generation microprocessor-based high-frequency double conversion technology, providing continuous power without interruptions.

This system combines advanced DSP (Digital Signal Processing) with three-level architecture, ensuring efficient power management and minimal energy loss—up to 95% efficiency, rising to 98% in eco mode. The built-in Active Power Factor Correction (APFC) optimizes power usage, reaching a power factor of 0.99.

With an output power factor of 0.9, the UPS delivers stable and robust energy to critical applications. Thanks to EnerTech’s digital parallel technology, it supports seamless scalability and redundancy.

It features a wide input voltage range of 140–300 VAC with 50/60 Hz auto-sensing, making it compatible with various power sources. The cold start capability ensures the UPS can operate even without mains power.

Optimized for cooling, the system includes rear ventilation and a variable-speed fan for temperature control. Built-in software and hardware protection features guard against electrical issues to ensure uninterrupted performance.

Fast battery recovery recharges up to 90% capacity within 3 hours. Smart battery features like automatic floating/equalizing control and charger dormancy extend battery life by up to 50%, enhancing overall system reliability and lifespan.

Key Features & Benefits

  • High frequency on-line double conversion technology.
  • Advanced DSP and 3-level technology.
  • High efficiency 95% (up to 98% in ECO mode).
  • Active power factor correction (APFC).
  • Input power factor up to 0.99.
  • Output power factor 0.9.
  • Advanced digital parallel technology.
  • Wide input voltage range (140 V ~ 300 Vac).
  • 50 / 60 Hz frequency auto sensing.
  • Cold start.
  • Rear ventilation design and variable speed fan.
  • Effective software and hardware protection.
  • Quick and stable charging, 90% capacity restored
    in 3 h (standard model UPS).
  • Intelligent battery management, automatic floating /
    equalizing charge control, charger dormancy control,
    increasing battery life by 50%.
sr d 1 3

Specifications

Input
DC Voltage140 – 280 V
Input Frequency50 / 60 Hz (auto-sensing)
Input Power Factor>=0.99
Output Voltage
Nominal Output Voltage208 / 220 / 230 / 240 Vac (settable via LCD)
WaveformSinewave
Frequency45 ~ 55 Hz or 55 ~ 65 Hz (synchronized); 50 / 60 Hz ± 0.1 Hz (battery mode)
THD<=1% (linear load), <=5% (non-linear load)
Crest Factor3:1
Inverter TechnologyDouble conversion, Microprocessor based IGBT, PWM Technology
Overload Capacity105% ~ 125% for 1 min, 125% ~ 150% for 30s, >150% for 300 ms
Change Over Time0 sec
Battery
Nominal Battery Voltage VDC96 / 120 / 180 / 192 V
TypeSealed Maintenance Free (SMF-VRLA) / Lead Acid -Tubular
ProtectionDC over, DC under, Short Circuit, Overload, AC under, AC over
Indication
LCD & LEDMains ON, UPS ON, Battery %, Load %, AC/DC under/over, Overload
MeteringInput V, Output V, Input Frequency, DC V, Batt I, Input I, Output I
General
Efficiency> 90% to 98% in ECO mode
Noise (above ambient)< 50 db at 1 mtr
CoolingForced Air Cooling
CommunicationRS232 (standard), USB / RS485 / dry contacts / SNMP / battery temp. compensation (optional)
Transfer TimeMains mode to battery: 0 ms; Inverter to bypass: 4 ms (typical)
ProtectionsShort-circuit, overload, overtemperature, battery discharge, fan test
DisplayLCD + LED
Standards
EN 62040-1, EN 62040-2, EN 61000-3-2, EN 61000-3-3, IEC 61000-4-2, IEC 61000-4-3, IEC 61000-4-4, IEC 61000-4-5, IEC 61000-4-6, IEC 61000-4-8, IEC 61000-4-11, IEC 61000-2-2, IEC 62040-2, IEC 62040-1, IEC 62040-3
Environment
Operating Temperature0°C ~ 45°C
Storage Temperature-25°C ~ 55°C (without batteries)

Range Of Online UPS

Enertech

Helpful Faq’s

Yes, despite the removal of Government Feed-in Tariff, installs have been forecast to continue at the current rate and even increase in 2023.

Yes, despite the removal of Government Feed-in Tariff, installs have been forecast to continue at the current rate and even increase in 2023.

Yes, despite the removal of Government Feed-in Tariff, installs have been forecast to continue at the current rate and even increase in 2023.

Yes, despite the removal of Government Feed-in Tariff, installs have been forecast to continue at the current rate and even increase in 2023.

    Book A Call With Our Sales Expert

      Call Now Button